Skip to main content Skip to search Skip to main navigation
FAST DELIVERY TIMES
OVER 120,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

2737630000

Weidmüller 2737630000 Combiner Box (Photovoltaik), PV Next, 1000 V, 6 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland

Product information "Weidmüller 2737630000 Combiner Box (Photovoltaik), PV Next, 1000 V, 6 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland"

Weidmüller Combiner Box (Photovoltaik), PV Next, 1000 V, 6 MPP´s, 2 Inputs / 1 Output per MPP, Surge protection I / II, Cable gland

Weidmüller 2737630000

EAN 04050118824902

Description

Combiner box for inverters with 6 MPP tracker, suitable for protecting the DC side of a photovoltaic system according to DIN CLC/TS 51643-32. MPP1: 2 inputs, connection via M25 cable gland with multiple sealing inserts. PUSH IN connection / single-wire, multi-wire, with/without ferrule. 1 output, connection via M25 cable gland with multiple sealing inserts. PUSH IN connection / single-wire, multi-wire, with/without ferrule. MPP2 to 6: identical to MPP1 Max. string voltage Uoc: 1000 VDC 1 class/type I + II combined arrester with signal contact Connection of the signal contact via M16 cable glands (Clamping range 5-10 mmØ) max. conductor cross-section: 1.5 mm² Connection of the functional earth via M16 cable glands (Clamping range 5-10 mmØ) Conductor cross-section: >= 16 mm² Protection class: IP65 All built into a glas fibre reinforced polyester housing. Dimensions HxWxD: 330x558x175 mm Approval according to low voltage switchgear and controlgear IEC 61439-1 and EN 61439-2Combiner box for inverters with 10 MPP tracker, suitable for protecting the DC side of a photovoltaic system according to DIN CLC/TS 51643-32. MPP1: 2 inputs, connection via WM4 C connector, compatible with cable type TÜV 2 Pfg1169/08.07 / EN 50618:2063 1 output, connection via WM4 C connector, compatible with cable type TÜV 2 Pfg1169/08.07 / EN 50618:2063 MPP2 to 10: identical to MPP1 Max. string voltage Uoc: 1100 VDC 1 class/type I + II combined arrester with signal contact Connection of the signal contact via M16 cable glands (Clamping range 5-10 mmØ) max. conductor cross-section: 1.5 mm² Connection of the functional earth via M16 cable glands (Clamping range 5-10 mmØ) Conductor cross-section: >= 16 mm² Protection class: IP65 All built into a glas fibre reinforced polyester housing. Dimensions HxWxD: 4695x600x2554 mm Approval according to low voltage switchgear and controlgear IEC 61439-1 and EN 61439-2

Documents & Downloads

Product Attributes

Width558 mm
Depth175 mm

Technical data

P/N (Part Number)2737630000
EAN04050118824902
ETIMEC003857
SCIPbdab5698-6a20-4370-8e28-8810d882d01a
Weight6.94 kg
Weight (packaged)8.77 kg

Designations

Combiner Box DC Box Generator connection box PV Box String Box

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.