GW95236
GEWISS GW95236 COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 100 - 2P CURVE C 10A TYPE A Idn=0,3A - 2 MODULES

€233.88
% €303.45 (22.93% saved)
Available, delivery time: 4-6 Bussines days
  Product number:    WST8810045762  
Manufacturer: GEWISSP/N: GW95236
Product information "GEWISS GW95236 COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 100 - 2P CURVE C 10A TYPE A Idn=0,3A - 2 MODULES"
GEWISS COMPACT RESIDUAL CURRENT CIRCUIT BREAKER WITH OVERCURRENT PROTECTION - MDC 100 - 2P CURVE C 10A TYPE A Idn=0,3A - 2 MODULES
GEWISS GW95236
EAN 8011564075221
Description
 90 RCD Range Modular circuit breakers for residual current protection. The 90 RCD range meets any ground fault protection requirement for any area of application. The range comprises MDC compact residual current c.b. with overcurrent protection. (from 6 to 32 A, curves B and C, up to 10 kA and lΔn from 30 and 300 mA type AC, A, A[IR] and A[S] and F) BD and BDHP, add-on residual current devices for circuit breakers MT and MTHP (lΔn from 10 mA to 3 A type AC, A, A[IR], A[S] and A adjustable) IDP residual current circuit breakers (up to 125 A, lΔn from 10 to 500 mA type AC, A, A[IR], A[S], F, B). 
Documents & Downloads
Product Attributes
| Anschlussquerschnitt flexible Leiter | <=1x35 - <=2x16 - <=1x16+2x10 mm² | 
|---|---|
| Anschlussquerschnitt starre Leiter | <=1x35 - <=2x16 - <=1x16+2x10 mm² | 
| Anz. Pole | 2P | 
| Anz. TE EN 50022 | 2 | 
| Anzahl TE EN 50022 | 2.0 | 
| Anzugsdrehmoment | 2 Nm | 
| Artikelnr. | MDC 100 | 
| Bemessungs- frequenz (Hz) | 50/60 Hz | 
| Bemessungs- spannung | 230.0 V | 
| Bemessungs- strom | 10.0 A | 
| Bemessungsfehlerstrom | 300 mA | 
| Bemessungsspannung (EN/IEC 61009-1, 61009-2-1) | 230/240 V | 
| Bemessungsstoß spannungsfestigkeit (Uimp) | 4.0 kV | 
| Beschreibung | FEHLERSTROM-LEITUNGSSCHUTZSCHALTER | 
| Betriebstemperatur | -25 +60° C (Derating In T>30° C) | 
| Charakteristik | C | 
| Doppelter Anschluss | JA (nur unten) | 
| Elektrische Lebensdauer | 10.000 | 
| Energiebegrenzungsklasse | 3.0 | 
| Gruppe | xyz | 
| Idn | 300.0 mA | 
| Isolationsspannung (Ui) | 500.0 V | 
| Kompatibilität zu elektrischen Hilfsschaltern | Ja | 
| Lagertemperatur | -40 +70 °C | 
| Mechanische Lebensdauer | 20.000 | 
| Norm | IEC/EN 61009-1, IEC/EN 61009-2-1 | 
| Position Montage | Jeder | 
| Schaltvermögen EN 60947-2 (Ics) | 50% Icu | 
| Schaltvermögen EN 61009-1 (Ics) | 0,75 x Icn | 
| Stoßstromfestigkeit (8/20 µs) | 250.0 A | 
| Typ | A | 
| Überspannungs- kategorie | III | 
Technical data
| P/N (Part Number) | GW95236 | 
|---|---|
| EAN | 8011564075221 | 
| ETIM | EC000905 | 
| Weight | 0.2292 kg | 
| Weight (packaged) | 0.2292 kg | 
Designations
 RCCB 
Login
 No reviews found. Share your insights with others. 