Skip to main content
FAST DELIVERY TIMES
OVER 40,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

A9Z66440

Schneider Electric A9Z66440 Residual Current Circuit Breaker All-Current Sensitive iID, 4P, 40A, Type B-SI, 500mA

Product information "Schneider Electric A9Z66440 Residual Current Circuit Breaker All-Current Sensitive iID, 4P, 40A, Type B-SI, 500mA"

Schneider Electric Residual Current Circuit Breaker All-Current Sensitive iID, 4P, 40A, Type B-SI, 500mA

Schneider Electric A9Z66440

EAN 3606489502904

Description

The Acti 9 iID residual current circuit breaker is all-current sensitive. It features a four-pole design, a nominal current of 40A, a type B-SI, a nominal fault current of 500mA, an operating voltage (Ue) of 400V AC at 50Hz, and an insulation voltage of 500V AC. It has a flicker-free switching mechanism for reduced wear and tear on contacts. It includes a mechanical VisiTrip fault indication on the front to show trip events caused by residual currents. The VisiSafe contact indication assures safety and indicates the absence of voltage on the output side when displayed in green. A test button is available for regular functional checks. Dual terminal blocks allow for cable or busbar connections on both sides. Easy removal of individual devices from an installed busbar, thanks to the accessible front mounting element. Additional auxiliary modules can be mounted as an option, such as an undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), status auxiliary switch (iOF), and fault signal switch (iSD). Type B-SI incorporates SI technology, providing enhanced resistance to electrical disturbances. It protects against smooth DC residual currents in single or three-phase supply networks caused by frequency converters, inverters & emergency power supplies. Color RAL 9003. Meets the following standards: IEC/EN 61008-2-1, IEC/EN 62423, IEC 61543, VDE 0664.

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 40A
Bemessungsfehlerstrom 0.5A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 1.8W
Montageart DIN-Schiene
Fehlerstrom-Typ B
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 3kA
Spannungsart AC
Mit Verriegelungsvorrichtung
Frequenz 50 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z66440
EAN3606489502904
ETIMEC000003
SCIP9e5fad0d-c8bc-4b0a-9fc6-957682374c40
ECLASSeClass_10_AAB906014
Weight0.428 kg
Weight (packaged)0.428 kg

Designations

RCCB RCD Type B RCD Type B-SI Type B Type B SI TypeB all-current sensitive RCCB all-current sensitive RCD residual current circuit breaker residual current circuit breaker Type B residual current circuit breaker Type B-SI residual current circuit breaker TypeB residual current device

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.