Skip to main content
FAST DELIVERY TIMES
OVER 40,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

A9Z26440

Schneider Electric A9Z26440 Residual Current Circuit Breaker iID, 4P, 40A, 500mA, Type A

Product information "Schneider Electric A9Z26440 Residual Current Circuit Breaker iID, 4P, 40A, 500mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 4P, 40A, 500mA, Type A

Schneider Electric A9Z26440

EAN 3606480443237

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 40A, earth fault sensitivity 500mA, earth leakage protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection for indirect contact, for example, in the case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution units (500mA). Switching and disconnecting of circuits. Step switching for low-wear switching of contacts. With mechanical front-side fault indication (VisiTrip) for displaying tripping due to overload or short circuit. Safe contact indication (VisiSafe) of the residual current device when green, ensuring that no voltage is present on the outgoing side. Test button for regular function testing. Double connection terminals for connection of cables or busbars on both sides. Easy removal of individual devices when busbar is installed, thanks to the front-accessible fixing element. Additional optional side-mounted auxiliary modules - undervoltage release (iMN), overvoltage trip (iMSU), shunt trip (iMX), auxiliary switch for status notification (iOF), fault signal switch (iSD). Tool-free mounting on the left side of the device. Color RAL 9003. The residual current circuit breaker iID satisfies the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!.
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 40A
Bemessungsfehlerstrom 0.5A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.8W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 3kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z26440
EAN3606480443237
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.37 kg
Weight (packaged)0.37 kg

Designations

Earth fault circuit breaker Fault current RCCB RCCB RCD Residual current circuit breaker Residual current device Type A

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!