€289.16*
% €403.41* (28.32% saved)Available, delivery time: 6-10 Bussines days
Product number: WST8810009298
Manufacturer: Schneider ElectricP/N: A9Z25463
Product information "Schneider Electric A9Z25463 Residual Current Circuit Breaker iID, 4P, 63A, 300mA, Type A selective"
Schneider Electric Residual Current Circuit Breaker iID, 4P, 63A, 300mA, Type A selective
Schneider Electric A9Z25463
EAN 3606480443299
Description
The Acti 9 iID residual current circuit breaker, 1.5kA (IEC/EN 61008-1), features 4 poles, rated current of 63A, earth leakage sensitivity of 300mA, earth fault protection class Type A, selective, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. It ensures additional protection in case of direct contact (≤ 30mA). It provides fault protection in case of indirect contact, such as insulation faults (≥ 100mA, ≤ 300mA). It also offers fault protection in construction power distribution (500mA). The device is capable of switching and disconnecting circuits. Its quick make-break mechanism ensures low-wear operation of contacts. Equipped with a front mechanical fault indicator (VisiTrip) for displaying overloads or short circuits. The safe contact indicator (VisiSafe) of the residual current circuit breaker, when green, ensures safety from live voltage on the output side. It features a test button for regular functional checks. The device has double connection terminals for connecting cables or busbars on both sides. The individual unit can be easily removed with an installed busbar, thanks to the front-accessible mounting element. The selective version ensures correct selection between different residual current devices and the tripping of the device closest to the fault. Additional auxiliary modules can be snapped on (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary contact for status indication (iOF), fault signaling switch (iSD). Tool-free mounting on the left side of the device. Color RAL 9003. The iID residual current circuit breaker meets the following standards: IEC/EN 61008-1 and IEC/EN 60947-2, and is also VDE certified!
Documents & Downloads
Product Attributes
Polzahl | 4 |
---|---|
Bemessungsspannung | 400V |
Bemessungsstrom | 63A |
Bemessungsfehlerstrom | 0.3A |
Bemessungsisolationsspannung Ui | 500V |
Bemessungsstoßspannungsfestigkeit Uimp | 6kV |
Verlustleistung | 3.5W |
Montageart | DIN-Schiene |
Fehlerstrom-Typ | A |
Selektiver-Typ | 1 |
Kurzzeitverzögerter Typ | 1 |
Kurzschlussfestigkeit (Icw) | -kA |
Stoßstromfestigkeit | 3kA |
Spannungsart | AC |
Mit Verriegelungsvorrichtung | 1 |
Frequenz | 50/60 Hz |
Zusatzeinrichtungen möglich | 1 |
Schutzart (IP) | IP20 |
Breite in Teilungseinheiten | 4 |
Einbautiefe | 44mm |
Umgebungstemperatur während des Betriebs | -25°C |
Verschmutzungsgrad | 3 |
Anschließbarer Leiterquerschnitt mehrdrähtig | 1mm² |
Anschließbarer Leiterquerschnitt eindrähtig | 1mm² |
RAL-Nummer (ähnlich) | |
Explosionsgeschützt |
Technical data
P/N (Part Number) | A9Z25463 |
---|---|
EAN | 3606480443299 |
ETIM | EC000003 |
SCIP | 6cb0708f-a1ac-4da2-b46f-e46ba9165efa |
ECLASS | eClass_10_AAB906014 |
Weight | 0.371 kg |
Weight (packaged) | 0.371 kg |
Designations
Fault current RCCB RCCB RCD RCD Residual Current Circuit Breaker Residual Current Device Type A