Skip to main content
FAST DELIVERY TIMES
OVER 40,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

A9Z25440

Schneider Electric A9Z25440 Residual current circuit breaker iID, 4P, 40A, 300mA, Type A selective

Product information "Schneider Electric A9Z25440 Residual current circuit breaker iID, 4P, 40A, 300mA, Type A selective"

Schneider Electric Residual current circuit breaker iID, 4P, 40A, 300mA, Type A selective

Schneider Electric A9Z25440

EAN 3606480443244

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current of 40A, earth fault sensitivity of 300mA, earth leakage protection class Type A, selective, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g. in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution boards (500mA). Switching and disconnecting of circuits. Jump switching for low-wear switching of contacts. With mechanical front-side fault indication (VisiTrip) for display of tripping due to overload or short circuit. Secure contact indication (VisiSafe) of the residual current circuit breaker, with a green display indicating safety of de-energization on the output side. Test button for regular function testing. Dual connection terminals for bidirectional connection of cables or busbars. Simple removal of the individual device with an installed busbar, thanks to the front-accessible mounting element. Selective version- to ensure the correct discrimination between different residual current circuit breakers and the triggering of the device closest to the fault. Additional modular accessories (optional)- undervoltage trip (iMN), overvoltage trip (iMSU), shunt trip (iMX), auxiliary switch for status reporting (iOF), fault signal switch (iSD). Tool-free assembly on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID complies with the following standards- IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 40A
Bemessungsfehlerstrom 0.3A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.8W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ 1
Kurzzeitverzögerter Typ 1
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 3kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z25440
EAN3606480443244
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.376 kg
Weight (packaged)0.376 kg

Designations

RCCB RCCB RCD RCD Type A earth leakage residual current circuit breaker residual current device