€184.24*
% €257.04* (28.32% saved)Available, delivery time: 6-10 Bussines days
Product number: WST8810009297
Manufacturer: Schneider ElectricP/N: A9Z25440
Product information "Schneider Electric A9Z25440 Residual current circuit breaker iID, 4P, 40A, 300mA, Type A selective"
Schneider Electric Residual current circuit breaker iID, 4P, 40A, 300mA, Type A selective
Schneider Electric A9Z25440
EAN 3606480443244
Description
Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current of 40A, earth fault sensitivity of 300mA, earth leakage protection class Type A, selective, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g. in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution boards (500mA). Switching and disconnecting of circuits. Jump switching for low-wear switching of contacts. With mechanical front-side fault indication (VisiTrip) for display of tripping due to overload or short circuit. Secure contact indication (VisiSafe) of the residual current circuit breaker, with a green display indicating safety of de-energization on the output side. Test button for regular function testing. Dual connection terminals for bidirectional connection of cables or busbars. Simple removal of the individual device with an installed busbar, thanks to the front-accessible mounting element. Selective version- to ensure the correct discrimination between different residual current circuit breakers and the triggering of the device closest to the fault. Additional modular accessories (optional)- undervoltage trip (iMN), overvoltage trip (iMSU), shunt trip (iMX), auxiliary switch for status reporting (iOF), fault signal switch (iSD). Tool-free assembly on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID complies with the following standards- IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!
Documents & Downloads
Product Attributes
Polzahl | 4 |
---|---|
Bemessungsspannung | 400V |
Bemessungsstrom | 40A |
Bemessungsfehlerstrom | 0.3A |
Bemessungsisolationsspannung Ui | 500V |
Bemessungsstoßspannungsfestigkeit Uimp | 6kV |
Verlustleistung | 3.8W |
Montageart | DIN-Schiene |
Fehlerstrom-Typ | A |
Selektiver-Typ | 1 |
Kurzzeitverzögerter Typ | 1 |
Kurzschlussfestigkeit (Icw) | -kA |
Stoßstromfestigkeit | 3kA |
Spannungsart | AC |
Mit Verriegelungsvorrichtung | 1 |
Frequenz | 50/60 Hz |
Zusatzeinrichtungen möglich | 1 |
Schutzart (IP) | IP20 |
Breite in Teilungseinheiten | 4 |
Einbautiefe | 44mm |
Umgebungstemperatur während des Betriebs | -25°C |
Verschmutzungsgrad | 3 |
Anschließbarer Leiterquerschnitt mehrdrähtig | 1mm² |
Anschließbarer Leiterquerschnitt eindrähtig | 1mm² |
RAL-Nummer (ähnlich) | |
Explosionsgeschützt |
Technical data
P/N (Part Number) | A9Z25440 |
---|---|
EAN | 3606480443244 |
ETIM | EC000003 |
SCIP | 6cb0708f-a1ac-4da2-b46f-e46ba9165efa |
ECLASS | eClass_10_AAB906014 |
Weight | 0.376 kg |
Weight (packaged) | 0.376 kg |
Designations
RCCB RCCB RCD RCD Type A earth leakage residual current circuit breaker residual current device