Schneider Electric A9Z24491 Residual Current Circuit Breaker iID, 4P, 100A, 300mA, Type A

Product information "Schneider Electric A9Z24491 Residual Current Circuit Breaker iID, 4P, 100A, 300mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 4P, 100A, 300mA, Type A

Schneider Electric A9Z24491

EAN 3606480443374

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 100A, earth leakage sensitivity 300mA, earth leakage protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Error protection in case of indirect contact, e.g., in the event of insulation faults (≥ 100mA, ≤ 300mA). Error protection in construction site power distribution systems (500mA). Switching and isolating circuits. Jump operation for low-wear switching of contacts. With mechanical front fault indication (VisiTrip) to display trippings due to overload or short circuit. Secure contact indication (VisiSafe) of the residual current circuit breaker when the display is green, indicates safety from voltage on the output side. Test button for regular function testing. Double connection terminals for bilateral connection of cables or phase bars. Easy removal of the individual device with an installed phase bar, thanks to the front-accessible fixing element. Additional adjacent auxiliary modules (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary switch for status reporting (iOF), error reporting switch (iSD). Tool-free mounting on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID complies with the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 100A
Bemessungsfehlerstrom 0.3A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 7W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z24491
EAN3606480443374
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.379 kg
Weight (packaged)0.379 kg

Designations

RCCB RCCB RCCB switch RCD Residual current Residual current circuit breaker Residual current device Type A