Skip to main content
FAST DELIVERY TIMES
OVER 40,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

A9Z24463

Schneider Electric A9Z24463 Residual current circuit breaker iID, 4P, 63A, 300mA, Type A

Product information "Schneider Electric A9Z24463 Residual current circuit breaker iID, 4P, 63A, 300mA, Type A"

Schneider Electric Residual current circuit breaker iID, 4P, 63A, 300mA, Type A

Schneider Electric A9Z24463

EAN 3606480443275

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 63A, earth fault sensitivity 300mA, earth fault protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection for indirect contact, e.g., in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution (500mA). Switching and disconnecting of circuits. Stepping mechanism for low-wear switching of contacts. With a mechanical front-side fault indication (VisiTrip) for displaying tripping due to overload or short circuit. Safe contact indicator (VisiSafe) of the residual current circuit breaker, green indicator ensures safety of absence of voltage on the outlet side. Test button for regular function checks. Double connection terminals for bilateral connection of cables or busbars. Simple removal of individual devices with a mounted busbar, thanks to the front-accessible mounting element. Additionally modular auxiliary modules (optional) - undervoltage release (iMN), overvoltage release (iMSU), operating current release (iMX), auxiliary switch for status indication (iOF), fault signal switch (iSD). Tool-less mounting on the left side of the device. Color RAL 9003. The residual current circuit breaker iID complies with the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Moreover, this series is VDE certified!
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 63A
Bemessungsfehlerstrom 0.3A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.5W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z24463
EAN3606480443275
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.371 kg
Weight (packaged)0.371 kg

Designations

RCCB RCCB RCD RCD Type A earth fault earth leakage circuit breaker residual current device

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!