Skip to main content
FAST DELIVERY TIMES
OVER 40,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

A9Z24440

Schneider Electric A9Z24440 Residual Current Circuit Breaker iID, 4P, 40A, 300mA, Type A

Product information "Schneider Electric A9Z24440 Residual Current Circuit Breaker iID, 4P, 40A, 300mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 4P, 40A, 300mA, Type A

Schneider Electric A9Z24440

EAN 3606480443220

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 40A, earth fault sensitivity 300mA, earth leakage protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g., due to insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution (500mA). Switching and disconnecting of circuits. Step switch for low-wear switching of contacts. With mechanical front fault indication (VisiTrip) for displaying tripping caused by overload or short circuit. Safe contact indication (VisiSafe) of the residual current circuit breaker, green indication ensures absence of voltage on the outgoing side. Test button for regular functional testing. Dual connection terminals for two-sided connection of cables or busbars. Easy removal of the individual device when busbars are installed, thanks to the front accessible fastening element. Additionally, side-by-side mountable auxiliary modules available (optional) - under-voltage release (iMN), over-voltage release (iMSU), shunt trip (iMX), status auxiliary switch (iOF), fault signal switch (iSD). Tool-free mounting on the left side of the device. Color RAL 9003. The residual current circuit breaker iID complies with the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Also, this series is VDE certified!.
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 40A
Bemessungsfehlerstrom 0.3A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.8W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z24440
EAN3606480443220
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.371 kg
Weight (packaged)0.371 kg

Designations

RCBO RCCB RCCB RCD RCD Type A residual current residual current circuit breaker

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!