Skip to main content
FAST DELIVERY TIMES
OVER 40,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

A9Z24425

Schneider Electric A9Z24425 Residual Current Circuit Breaker iID, 4P, 25A, 300mA, Type A

Product information "Schneider Electric A9Z24425 Residual Current Circuit Breaker iID, 4P, 25A, 300mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 4P, 25A, 300mA, Type A

Schneider Electric A9Z24425

EAN 3606480443183

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 25A, earth leakage sensitivity 300mA, earth leakage protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Provides additional protection in case of direct contact (≤ 30mA). Fault protection for indirect contact, e.g., insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction site distributors (500mA). Switching and disconnecting circuits. Step control for low-wear switching of contacts. With mechanical front side fault indication (VisiTrip) for display of overloads or short circuits. Safe contact indication (VisiSafe) of the residual current circuit breaker when green, indicating a de-energized state on the output side. Test button for regular functional testing. Double connection terminals for connection of cables or busbars on both sides. Easy removal of the individual unit when the busbar is installed, thanks to the front-accessible fastening element. Additionally, connectable auxiliary modules (optional) - under-voltage release (iMN), over-voltage release (iMSU), shunt trip (iMX), auxiliary switch for status notification (iOF), fault signaling switch (iSD). Tool-less assembly on the left side of the device. Color RAL 9003. The residual current circuit breaker iID complies with the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Moreover, this series is VDE certified!
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 25A
Bemessungsfehlerstrom 0.3A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.2W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z24425
EAN3606480443183
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.3774 kg
Weight (packaged)0.3774 kg

Designations

Earth Leakage Circuit Breaker Fault Current RCCB RCCB RCD Residual Current Circuit Breaker Residual Current Device Type A

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!