A9Z24263

Schneider Electric A9Z24263 Residual Current Circuit Breaker iID, 2P, 63A, 300mA, Type A

Product information "Schneider Electric A9Z24263 Residual Current Circuit Breaker iID, 2P, 63A, 300mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 2P, 63A, 300mA, Type A

Schneider Electric A9Z24263

EAN 3606480443077

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 2-pole, rated current 63A, earth fault sensitivity 300mA, earth fault protection class Type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 500V AC. Provides additional protection against direct contact (≤ 30mA). Fault protection against indirect contact, e.g., in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution boards (500mA). Switching and disconnecting of electrical circuits. Low-wear switching action of contacts. Equipped with a mechanical front-side fault indication (VisiTrip) to display tripping due to overload or short-circuit. Safe contact indication (VisiSafe) of the residual current circuit breaker, indicating safety from live contacts on the output side when the indicator is green. Test button for regular functional checks. Double connection terminals for bilateral connection of cables or busbars. Easy removal of the individual device when a busbar is installed, thanks to the front accessible mounting element. Additional auxiliary modules available (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary contact for status reporting (iOF), fault signaling switch (iSD). Tool-free mounting on the left side of the device. Colour RAL 9003. The residual current circuit breaker iID complies with the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!.
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 2
Bemessungsspannung 230V
Bemessungsstrom 63A
Bemessungsfehlerstrom 0.3A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.5W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 2
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z24263
EAN3606480443077
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.187 kg
Weight (packaged)0.202 kg

Designations

RCCB RCCB RCD RCD Type A earth leakage residual current circuit breaker residual current device