Schneider Electric Residual Current Circuit Breaker iID, 4P, 63A, 100mA, Type A

Schneider Electric A9Z22463

EAN 3606480443268

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 63A, earth fault sensitivity 100mA, earth leakage protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct touch (≤ 30mA). Fault protection at indirect touch, e.g., in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distributors (500mA). Switching and disconnecting of circuits. Pre-charged spring for wear-resistant switching of contacts. With mechanical front-side fault indicator (VisiTrip) to display trippings due to overload or short-circuit. Safe contact indicator (VisiSafe) of the residual current circuit breaker, green display ensures safety from live voltage on the output side. Test button for regular function testing. Double connection terminals for bilateral connection of cables or busbars. Easy removal of the individual unit when the busbar is installed, thanks to the front-accessible fixing element. Additionally dockable auxiliary modules (optional) - undervoltage release (iMN), overvoltage trip (iMSU), shunt trip (iMX), auxiliary switch for status reporting (iOF), fault signal switch (iSD). Tool-free mounting on the left side of the device. Color RAL 9003. The residual current circuit breaker iID complies with the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!.
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 63A
Bemessungsfehlerstrom 0.1A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.5W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z22463
EAN3606480443268
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.381 kg
Weight (packaged)0.381 kg

Designations

RCCB RCCB RCD Residual Current Residual Current Circuit Breaker Residual Current Device Residual Current Device Type A