Schneider Electric Residual Current Circuit Breaker iID, 2P, 40A, 100mA, Type A
Schneider Electric A9Z22240
EAN 3606480443022
Description
Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 2-pole, rated current 40A, earth fault sensitivity 100mA, earth fault protection class type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 500V AC. Provides additional protection in case of direct contact (≤ 30mA). Error protection in case of indirect contact, e.g. insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution systems (500mA). Switching and disconnecting circuits. Pre-arc switching for low-wear contact switching. With mechanical front side fault indication (VisiTrip) for displaying overloads or short-circuits. Safe contact indication (VisiSafe) of the residual current circuit breaker, green display indicates safety from voltage presence on the output side. Test button for regular functional testing. Dual connection terminals for double-sided connection of cables or phase bars. Simple removal of the individual device when a phase bar is installed, thanks to the front-accessible fastening element. Additional auxiliary modules that can be attached (optional) - under voltage trip (iMN), over-voltage trip (iMSU), working current trip (iMX), auxiliary switch for status reporting (iOF), fault signal switch (iSD). Tool-free mounting on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID meets the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. This series is also VDE certified!.
Documents & Downloads
Product Attributes
Polzahl | 2 |
---|---|
Bemessungsspannung | 230V |
Bemessungsstrom | 40A |
Bemessungsfehlerstrom | 0.1A |
Bemessungsisolationsspannung Ui | 500V |
Bemessungsstoßspannungsfestigkeit Uimp | 6kV |
Verlustleistung | 3.8W |
Montageart | DIN-Schiene |
Fehlerstrom-Typ | A |
Selektiver-Typ | |
Kurzzeitverzögerter Typ | |
Kurzschlussfestigkeit (Icw) | -kA |
Stoßstromfestigkeit | 0.25kA |
Spannungsart | AC |
Mit Verriegelungsvorrichtung | 1 |
Frequenz | 50/60 Hz |
Zusatzeinrichtungen möglich | 1 |
Schutzart (IP) | IP20 |
Breite in Teilungseinheiten | 2 |
Einbautiefe | 44mm |
Umgebungstemperatur während des Betriebs | -25°C |
Verschmutzungsgrad | 3 |
Anschließbarer Leiterquerschnitt mehrdrähtig | 1mm² |
Anschließbarer Leiterquerschnitt eindrähtig | 1mm² |
RAL-Nummer (ähnlich) | |
Explosionsgeschützt |
Technical data
P/N (Part Number) | A9Z22240 |
---|---|
EAN | 3606480443022 |
ETIM | EC000003 |
SCIP | 6cb0708f-a1ac-4da2-b46f-e46ba9165efa |
ECLASS | eClass_10_AAB906014 |
Weight | 0.205 kg |
Weight (packaged) | 0.22 kg |