A9Z22240

Schneider Electric A9Z22240 Residual Current Circuit Breaker iID, 2P, 40A, 100mA, Type A

Product information "Schneider Electric A9Z22240 Residual Current Circuit Breaker iID, 2P, 40A, 100mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 2P, 40A, 100mA, Type A

Schneider Electric A9Z22240

EAN 3606480443022

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 2-pole, rated current 40A, earth fault sensitivity 100mA, earth fault protection class type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 500V AC. Provides additional protection in case of direct contact (≤ 30mA). Error protection in case of indirect contact, e.g. insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution systems (500mA). Switching and disconnecting circuits. Pre-arc switching for low-wear contact switching. With mechanical front side fault indication (VisiTrip) for displaying overloads or short-circuits. Safe contact indication (VisiSafe) of the residual current circuit breaker, green display indicates safety from voltage presence on the output side. Test button for regular functional testing. Dual connection terminals for double-sided connection of cables or phase bars. Simple removal of the individual device when a phase bar is installed, thanks to the front-accessible fastening element. Additional auxiliary modules that can be attached (optional) - under voltage trip (iMN), over-voltage trip (iMSU), working current trip (iMX), auxiliary switch for status reporting (iOF), fault signal switch (iSD). Tool-free mounting on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID meets the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. This series is also VDE certified!.
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 2
Bemessungsspannung 230V
Bemessungsstrom 40A
Bemessungsfehlerstrom 0.1A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.8W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 2
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z22240
EAN3606480443022
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.205 kg
Weight (packaged)0.22 kg

Designations

RCCB RCCB RCD RCD Type A earth leakage earth leakage circuit breaker residual current device

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!