€1,308.44*
% €1,825.46* (28.32% saved)Available, delivery time: 6-10 Bussines days
Product number: WST8810009281
Manufacturer: Schneider ElectricP/N: A9Z21491
Product information "Schneider Electric A9Z21491 Residual Current Circuit Breaker iID, 4P, 100A, 30mA, Type A"
Schneider Electric Residual Current Circuit Breaker iID, 4P, 100A, 30mA, Type A
Schneider Electric A9Z21491
EAN 3606480443350
Description
Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 100A, earth leakage sensitivity 30mA, earth leakage protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g., due to insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution boards (500mA). Switching and disconnecting of circuits. Snap action for low-wear switching of contacts. With mechanical on-front fault indication (VisiTrip) to display trippings caused by overload or short circuit. Safe contact indication (VisiSafe) for the residual current device, green indicator ensures safety from voltage on the output side. Test button for regular performance testing. Double connection terminals for dual side wiring of cables or busbars. Easy removal of the individual device with installed busbar, thanks to the accessible mounting element on the front side. Additional auxiliary modules can be attached (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary contact for status messaging (iOF), error reporting switch (iSD). Tool-less mounting on the left side of the device. Color RAL 9003. The residual current circuit breaker iID complies with the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Also, this series is VDE certified!
Documents & Downloads
Product Attributes
Polzahl | 4 |
---|---|
Bemessungsspannung | 400V |
Bemessungsstrom | 100A |
Bemessungsfehlerstrom | 0.03A |
Bemessungsisolationsspannung Ui | 500V |
Bemessungsstoßspannungsfestigkeit Uimp | 6kV |
Verlustleistung | 7W |
Montageart | DIN-Schiene |
Fehlerstrom-Typ | A |
Selektiver-Typ | |
Kurzzeitverzögerter Typ | |
Kurzschlussfestigkeit (Icw) | -kA |
Stoßstromfestigkeit | 0.25kA |
Spannungsart | AC |
Mit Verriegelungsvorrichtung | 1 |
Frequenz | 50/60 Hz |
Zusatzeinrichtungen möglich | 1 |
Schutzart (IP) | IP20 |
Breite in Teilungseinheiten | 4 |
Einbautiefe | 44mm |
Umgebungstemperatur während des Betriebs | -25°C |
Verschmutzungsgrad | 3 |
Anschließbarer Leiterquerschnitt mehrdrähtig | 1mm² |
Anschließbarer Leiterquerschnitt eindrähtig | 1mm² |
RAL-Nummer (ähnlich) | |
Explosionsgeschützt |
Technical data
P/N (Part Number) | A9Z21491 |
---|---|
EAN | 3606480443350 |
ETIM | EC000003 |
SCIP | 6cb0708f-a1ac-4da2-b46f-e46ba9165efa |
ECLASS | eClass_10_AAB906014 |
Weight | 0.428 kg |
Weight (packaged) | 0.428 kg |
Designations
RCCB RCCB RCD RCD Residual Current Residual Current Circuit Breaker Residual Current Device Type A