Skip to main content
FAST DELIVERY TIMES
OVER 40,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

A9Z21480

Schneider Electric A9Z21480 Residual Current Circuit Breaker iID, 4P, 80A, 30mA, Type A

Product information "Schneider Electric A9Z21480 Residual Current Circuit Breaker iID, 4P, 80A, 30mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 4P, 80A, 30mA, Type A

Schneider Electric A9Z21480

EAN 3606480443305

Description

The Acti 9 iID residual current circuit breaker, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 80A, earth fault sensitivity 30mA, earth fault protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g., in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distributors (500mA). Switching and disconnecting of circuits. Snap action for low-wear switching of contacts. With mechanical front-side fault indication display (VisiTrip) to indicate trippings by overload or short circuit. Safe contact display (VisiSafe) of the residual current circuit breaker when the display is green indicating safety from live voltage on the output side. Test button for regular functional testing. Dual connection terminals for connecting cables or busbars on both sides. Simple removal of the individual device when a busbar is installed, thanks to the front-accessible fastening element. Additionally connectable auxiliary modules (optional)- undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary switch for status indication (iOF), fault signaling switch (iSD). Tool-free mounting on the left side of the device. Color RAL 9003. The iID residual current circuit breaker meets the following standards- IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!.
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 80A
Bemessungsfehlerstrom 0.03A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 5.6W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z21480
EAN3606480443305
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.427 kg
Weight (packaged)0.427 kg

Designations

RCCB RCCB RCD Type A earth leakage earth leakage circuit breaker residual current circuit breaker residual current device

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.