A9Z21463

Schneider Electric A9Z21463 Residual Current Circuit Breaker iID, 4P, 63A, 30mA, Type A

Product information "Schneider Electric A9Z21463 Residual Current Circuit Breaker iID, 4P, 63A, 30mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 4P, 63A, 30mA, Type A

Schneider Electric A9Z21463

EAN 3606480443251

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 63A, earth fault sensitivity 30mA, earth fault protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Provides additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g., in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction site power distributors (500mA). Switching and isolating of electrical circuits. Step switching for low-wear operation of the contacts. With mechanical front-side fault indication (VisiTrip) for displaying trips due to overload or short circuit. Reliable contact indicator (VisiSafe) of the residual current circuit breaker, indicating safety of absence of voltage on the output side when the display is green. Test button for regular functional testing. Double connection terminals for bilateral connection of cables or busbars. Simple removal of the individual unit with the busbar installed, thanks to the front-accessible fixing element. Additional auxiliary modules that can be lined up (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary switch for status indication (iOF), fault signal switch (iSD). Tool-free left-side installation on the device. Color RAL 9003. The residual current circuit breaker iID meets the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 63A
Bemessungsfehlerstrom 0.03A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.5W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z21463
EAN3606480443251
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.427 kg
Weight (packaged)0.427 kg

Designations

RCCB RCCB RCCB switch RCD Type A residual current residual current circuit breaker residual current device