Skip to main content
FAST DELIVERY TIMES
OVER 40,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

A9Z21440

Schneider Electric A9Z21440 Residual Current Circuit Breaker (RCCB) Acti9-iID, 4-pole, 40A, 30mA, Type A

Product information "Schneider Electric A9Z21440 Residual Current Circuit Breaker (RCCB) Acti9-iID, 4-pole, 40A, 30mA, Type A"

Schneider Electric Residual Current Circuit Breaker (RCCB) Acti9-iID, 4-pole, 40A, 30mA, Type A

Schneider Electric A9Z21440

EAN 3606480443206

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 40A, earth fault sensitivity 30mA, earth fault protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection for indirect contact, e.g., in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distributors (500mA). Switching and disconnecting of circuits. Step switching for contact saving operations. With mechanical front-side fault indication (VisiTrip) to display trips due to overload or short-circuit. Safe contact indication (VisiSafe) of the RCCB, with green indication safety from voltage presence on the outgoing side. Test button for regular function testing. Dual connection terminals for bilateral connection of cables or busbars. Easy removal of individual devices with installed busbar, thanks to the front-side accessible fastening element. Additionally connectable auxiliary modules (optional) - under voltage release (iMN), over voltage release (iMSU), shunt trip (iMX), auxiliary switch for status reporting (iOF), fault signal switch (iSD). Tool-free mounting on the left side of the device. Color shade RAL 9003. The RCCB iID meets the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. This series is also VDE certified!
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 40A
Bemessungsfehlerstrom 0.03A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.8W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z21440
EAN3606480443206
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.379 kg
Weight (packaged)0.379 kg

Designations

RCCB RCCB RCCB protective device RCCB switch RCD Type A residual current residual current circuit breaker

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.