Skip to main content
FAST DELIVERY TIMES
OVER 40,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

A9Z21425

Schneider Electric A9Z21425 Residual Current Circuit Breaker iID, 4P, 25A, 30mA, Type A

Product information "Schneider Electric A9Z21425 Residual Current Circuit Breaker iID, 4P, 25A, 30mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 4P, 25A, 30mA, Type A

Schneider Electric A9Z21425

EAN 3606480443176

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 25A, ground fault sensitivity 30mA, ground fault protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection on direct contact (≤ 30mA). Fault protection on indirect contact, e.g., in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction site power distributions (500mA). Switching and disconnecting of circuits. Jump switch for wear-reduced switching of contacts. With mechanical front-side fault indication (VisiTrip) showing tripping through overload or short-circuit. Safe contact indication (VisiSafe) of the residual current device, green indication means safety from voltage on the outgoing side. Test button for regular function checks. Dual connection terminals for bilateral connection of cables or busbars. Easy removal of the single device with an installed busbar, thanks to the frontally accessible fastening element. Additionally, auxiliary modules can be mounted (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary switch for status messages (iOF), fault signal switch (iSD). Tool-free mounting on the left side of the device. Color RAL 9003. The residual current circuit breaker iID complies with the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Moreover, this series is VDE certified!
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 25A
Bemessungsfehlerstrom 0.03A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.2W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z21425
EAN3606480443176
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.3775 kg
Weight (packaged)0.3775 kg

Designations

Earth leakage circuit breaker RCCB RCD Residual current Residual current circuit breaker Residual current device Safety switch Type A

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.