A9Z21263

Schneider Electric A9Z21263 Residual Current Circuit Breaker iID, 2P, 63A, 30mA, Type A

Product information "Schneider Electric A9Z21263 Residual Current Circuit Breaker iID, 2P, 63A, 30mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 2P, 63A, 30mA, Type A

Schneider Electric A9Z21263

EAN 3606480443053

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 2-pole, rated current 63A, ground fault sensitivity 30mA, ground fault protection class Type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 500V AC. Provides additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g., insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution (500mA). Switching and disconnecting circuits. Jump switch for wear-reduced switching of contacts. With mechanical front-side fault indication (VisiTrip) for displaying trips caused by overload or short circuit. Secure contact indication (VisiSafe) of the residual current device, with green indication safety of de-energized condition on the output side. Test button for regular functional testing. Double connection terminals for dual-sided connection of cables or phase bars. Simple removal of the individual device when the phase bar is installed, thanks to the front-accessible fixing element. Additionally connectable auxiliary modules (optional)- undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary switch for status reporting (iOF), fault signaling switch (iSD). Tool-free assembly on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID meets the following standards- IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!.
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 2
Bemessungsspannung 230V
Bemessungsstrom 63A
Bemessungsfehlerstrom 0.03A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.5W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 2
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z21263
EAN3606480443053
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.2185 kg
Weight (packaged)0.234 kg

Designations

RCCB RCCB RCD RCD Type A earth leakage circuit breaker fault current residual current device