Skip to main content
FAST DELIVERY TIMES
OVER 40,000 ELECTRICAL AND INDUSTRIAL PRODUCTS

A9Z21240

Schneider Electric A9Z21240 Residual Current Circuit Breaker iID, 2P, 40A, 30mA, Type A

Product information "Schneider Electric A9Z21240 Residual Current Circuit Breaker iID, 2P, 40A, 30mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 2P, 40A, 30mA, Type A

Schneider Electric A9Z21240

EAN 3606480443015

Description

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 2-pole, rated current 40A, earth leakage sensitivity 30mA, earth fault protection class Type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g. in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution (500mA). Switching and disconnecting of circuits. Jump switching for reduced-wear contact switching. With mechanical front-side fault indication (VisiTrip) showing tripping due to overload or short circuit. Safe contact indication (VisiSafe) of the residual current device, with green indicator ensuring verification of de-energization on the load side. Test button for regular functional checks. Dual-connection terminals for both sides connection of cables or busbars. Easy removal of the individual device with an installed busbar, thanks to the front-accessible mounting element. Additional auxiliary modules (optional) - under-voltage release (iMN), over-voltage release (iMSU), shunt trip (iMX), auxiliary contact for status indication (iOF), fault-signalising switch (iSD). Tool-free mounting on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID meets the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified!
GreenPremium Badge
Green Premium

Product Attributes

Polzahl 2
Bemessungsspannung 230V
Bemessungsstrom 40A
Bemessungsfehlerstrom 0.03A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.8W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 2
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technical data

P/N (Part Number)A9Z21240
EAN3606480443015
ETIMEC000003
SCIP6cb0708f-a1ac-4da2-b46f-e46ba9165efa
ECLASSeClass_10_AAB906014
Weight0.207 kg
Weight (packaged)0.222 kg

Designations

Fault current RCCB RCCB RCCB RCCB switch RCD Residual current circuit breaker Type A

0 of 0 reviews

Average rating of 0 out of 5 stars