Manufacturer: Schneider ElectricP/N: A9Z20216
Product information "Schneider Electric A9Z20216 Residual Current Circuit Breaker iID, 2P, 16A, 10mA, Type A"
Schneider Electric Residual Current Circuit Breaker iID, 2P, 16A, 10mA, Type A
Schneider Electric A9Z20216
EAN 3606480442971
Description
Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 2-pole, rated current 16A, earth fault sensitivity 10mA, earth fault protection class Type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g., due to insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction site power distribution systems (500mA). Switching and disconnecting of circuits. Snap action switching for low-wear contact operation. With VisiTrip, a mechanical front indicator for detecting overloads or short-circuits. VisiSafe contact indication for the residual current device, green indicator ensures no live voltage on the output side. Test button for regular functional testing. Dual connection terminals for both side wiring of cables or busbars. Easy removal of the individual device when a busbar is installed, thanks to the front-accessible fixing element. Additional modular accessories (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary switch for status indication (iOF), fault signal switch (iSD). Tool-free installation on the left side of the device. Color RAL 9003. This range of residual current circuit breakers meets the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Additionally, this series is VDE certified!
Documents & Downloads
Product Attributes
Polzahl | 2 |
---|---|
Bemessungsspannung | 230V |
Bemessungsstrom | 16A |
Bemessungsfehlerstrom | 0.01A |
Bemessungsisolationsspannung Ui | 500V |
Bemessungsstoßspannungsfestigkeit Uimp | 6kV |
Verlustleistung | 1.3W |
Montageart | DIN-Schiene |
Fehlerstrom-Typ | A |
Selektiver-Typ | |
Kurzzeitverzögerter Typ | |
Kurzschlussfestigkeit (Icw) | -kA |
Stoßstromfestigkeit | 0.25kA |
Spannungsart | AC |
Mit Verriegelungsvorrichtung | 1 |
Frequenz | 50/60 Hz |
Zusatzeinrichtungen möglich | 1 |
Schutzart (IP) | IP20 |
Breite in Teilungseinheiten | 2 |
Einbautiefe | 44mm |
Umgebungstemperatur während des Betriebs | -25°C |
Verschmutzungsgrad | 3 |
Anschließbarer Leiterquerschnitt mehrdrähtig | 1mm² |
Anschließbarer Leiterquerschnitt eindrähtig | 1mm² |
RAL-Nummer (ähnlich) | |
Explosionsgeschützt |
Technical data
P/N (Part Number) | A9Z20216 |
---|---|
EAN | 3606480442971 |
ETIM | EC000003 |
SCIP | 6cb0708f-a1ac-4da2-b46f-e46ba9165efa |
ECLASS | eClass_10_AAB906014 |
Weight | 0.212 kg |
Weight (packaged) | 0.227 kg |
Designations
RCCB RCCB RCCB protection switch RCCB switch RCD Type A residual current residual current circuit breaker