A9Z22491

Schneider Electric A9Z22491 Residual Current Circuit Breaker iID, 4P, 100A, 100mA, Type A

Productinformatie "Schneider Electric A9Z22491 Residual Current Circuit Breaker iID, 4P, 100A, 100mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 4P, 100A, 100mA, Type A

Schneider Electric A9Z22491

EAN 3606480443367

Beschrijving

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 100A, earth fault sensitivity 100mA, earth fault protection class type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g., in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction site distribution boards (500mA). Switching and isolating of circuits. Step switching for low-wear activation of contacts. Equipped with a mechanical front-side fault indication (VisiTrip) to show tripping due to overload or short circuit. Reliable contact indicator (VisiSafe) for the residual current device, with a green indicator ensuring the absence of voltage on the outgoing side. Test button for regular functional tests. Dual connection terminals for the connection of cables or busbars on both sides. Easy removal of the individual device with installed busbar, thanks to the front accessible fastening element. Additionally, connectable auxiliary modules (optional) - undervoltage release (iMN), overvoltage trip (iMSU), working current trip (iMX), auxiliary switch for status reporting (iOF), fault signaling switch (iSD). Tool-free assembly on the left side of the device. Color RAL 9003. The residual current circuit breaker iID meets the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. This series is also VDE certified!.

Productkenmerken

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 100A
Bemessungsfehlerstrom 0.1A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 7W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technische gegevens

P/N (Onderdeelnummer)A9Z22491
EAN3606480443367
ETIMEC000003
SCIPb078722f-7853-4e1e-a05b-29638f57b0ab
ECLASSeClass_10_AAB906014
Gewicht0.375 kg
Gewicht (verpakt)0.38 kg

Benamingen

RCB RCCB RCCB RCD Type A earth fault residual current circuit breaker residual current device