A9Z21491

Schneider Electric A9Z21491 Residual Current Circuit Breaker iID, 4P, 100A, 30mA, Type A

Productinformatie "Schneider Electric A9Z21491 Residual Current Circuit Breaker iID, 4P, 100A, 30mA, Type A"

Schneider Electric Residual Current Circuit Breaker iID, 4P, 100A, 30mA, Type A

Schneider Electric A9Z21491

EAN 3606480443350

Beschrijving

Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 100A, earth leakage sensitivity 30mA, earth leakage protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Ensures additional protection in case of direct contact (≤ 30mA). Fault protection in case of indirect contact, e.g., due to insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction power distribution boards (500mA). Switching and disconnecting of circuits. Snap action for low-wear switching of contacts. With mechanical on-front fault indication (VisiTrip) to display trippings caused by overload or short circuit. Safe contact indication (VisiSafe) for the residual current device, green indicator ensures safety from voltage on the output side. Test button for regular performance testing. Double connection terminals for dual side wiring of cables or busbars. Easy removal of the individual device with installed busbar, thanks to the accessible mounting element on the front side. Additional auxiliary modules can be attached (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary contact for status messaging (iOF), error reporting switch (iSD). Tool-less mounting on the left side of the device. Color RAL 9003. The residual current circuit breaker iID complies with the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Also, this series is VDE certified!

Productkenmerken

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 100A
Bemessungsfehlerstrom 0.03A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 7W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ
Kurzzeitverzögerter Typ
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 0.25kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Technische gegevens

P/N (Onderdeelnummer)A9Z21491
EAN3606480443350
ETIMEC000003
SCIPb078722f-7853-4e1e-a05b-29638f57b0ab
ECLASSeClass_10_AAB906014
Gewicht0.428 kg
Gewicht (verpakt)0.43 kg

Benamingen

RCCB RCCB RCD RCD Residual Current Residual Current Circuit Breaker Residual Current Device Type A