A9Z25463

Schneider Electric A9Z25463 ACTI9 IID 4P 63A 300MA-S A-TYPE INTERRUP

Informations sur le produit "Schneider Electric A9Z25463 ACTI9 IID 4P 63A 300MA-S A-TYPE INTERRUP"

Schneider Electric ACTI9 IID 4P 63A 300MA-S A-TYPE INTERRUP

Schneider Electric A9Z25463

EAN 3606480443299

Description

The Acti 9 iID residual current circuit breaker, 1.5kA (IEC/EN 61008-1), features 4 poles, rated current of 63A, earth leakage sensitivity of 300mA, earth fault protection class Type A, selective, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. It ensures additional protection in case of direct contact (≤ 30mA). It provides fault protection in case of indirect contact, such as insulation faults (≥ 100mA, ≤ 300mA). It also offers fault protection in construction power distribution (500mA). The device is capable of switching and disconnecting circuits. Its quick make-break mechanism ensures low-wear operation of contacts. Equipped with a front mechanical fault indicator (VisiTrip) for displaying overloads or short circuits. The safe contact indicator (VisiSafe) of the residual current circuit breaker, when green, ensures safety from live voltage on the output side. It features a test button for regular functional checks. The device has double connection terminals for connecting cables or busbars on both sides. The individual unit can be easily removed with an installed busbar, thanks to the front-accessible mounting element. The selective version ensures correct selection between different residual current devices and the tripping of the device closest to the fault. Additional auxiliary modules can be snapped on (optional) - undervoltage release (iMN), overvoltage release (iMSU), shunt trip (iMX), auxiliary contact for status indication (iOF), fault signaling switch (iSD). Tool-free mounting on the left side of the device. Color RAL 9003. The iID residual current circuit breaker meets the following standards: IEC/EN 61008-1 and IEC/EN 60947-2, and is also VDE certified!

Attributs du produit

Polzahl 4
Bemessungsspannung 400V
Bemessungsstrom 63A
Bemessungsfehlerstrom 0.3A
Bemessungsisolationsspannung Ui 500V
Bemessungsstoßspannungsfestigkeit Uimp 6kV
Verlustleistung 3.5W
Montageart DIN-Schiene
Fehlerstrom-Typ A
Selektiver-Typ 1
Kurzzeitverzögerter Typ 1
Kurzschlussfestigkeit (Icw) -kA
Stoßstromfestigkeit 3kA
Spannungsart AC
Mit Verriegelungsvorrichtung 1
Frequenz 50/60 Hz
Zusatzeinrichtungen möglich 1
Schutzart (IP) IP20
Breite in Teilungseinheiten 4
Einbautiefe 44mm
Umgebungstemperatur während des Betriebs -25°C
Verschmutzungsgrad 3
Anschließbarer Leiterquerschnitt mehrdrähtig 1mm²
Anschließbarer Leiterquerschnitt eindrähtig 1mm²
RAL-Nummer (ähnlich)
Explosionsgeschützt

Données techniques

P/N (Numéro de pièce)A9Z25463
EAN3606480443299
ETIMEC000003
SCIPb078722f-7853-4e1e-a05b-29638f57b0ab
ECLASSeClass_10_AAB906014
Poids0.371 kg
Poids (emballé)0.37 kg